GreenLight Request a quote
Drag to rotate the model

RM Monobloc Air-to-Water Heat Pump, R290, 8–22 kW

Air-to-water monobloc heat pump for heating, cooling and domestic hot water. Eco-friendly R290 refrigerant, A+++ class.

Model

Rated heating capacity (A7/W35)
8 kW
Heating W30/35: COP
4.28–5.45 W/W
Cooling W23/18: capacity
3.35–9.38 kW
Noise level (pressure at 1 m / power)
45 / 52 dB(A)
Dimensions (L×W×H)
1185×435×848 mm
Net / gross weight
89 / 95 kg

What is the RM heat pump

A heat pump for private homes: one outdoor unit heats the house in winter, cools it in summer and prepares hot water. Works with underfloor heating, radiators and fan coils; models from 8 to 22 kW.

How the RM heat pump works

The heat pump extracts heat from outdoor air even at −30 °C, the compressor raises its temperature, and the heat exchanger transfers the heat to the heating system water. It is a monobloc: the entire refrigerant circuit is factory-assembled inside the outdoor unit, and only water pipes run into the house.

RM heat pump: advantages

  • Operates at outdoor temperatures from −30 to +50 °C
  • Energy efficiency class A+++ at 35 °C
  • Heats water up to 75 °C
  • Natural R290 refrigerant, Panasonic compressor and Grundfos pump

RM heat pump: specifications

ParameterGL/RM-8GL/RM-15GL/RM-18GL/RM-22
Power supply, V/Ph/Hz 220–240/1/50220–240/1/50380–415/3/50380–415/3/50
Energy efficiency class 35 °C / 55 °C A+++ / A++A+++ / A++A+++ / A++A+++ / A++
Rated heating capacity (A7/W35), kW 8151822
Heating W30/35: capacity, kW 3.10–8.675.32–15.405.38–15.608.10–22.10
Heating W30/35: power input, kW 0.59–2.031.02–3.651.03–3.661.56–5.12
Heating W30/35: COP, W/W 4.28–5.454.21–5.284.26–5.324.32–5.22
Heating W47/55: capacity, kW 3.05–7.904.81–13.604.85–13.767.78–22.20
Heating W47/55: COP, W/W 2.80–3.242.85–3.072.88–3.122.85–3.36
Domestic hot water: capacity, kW 4.45–12.207.64–21.677.73–21.9511.60–30.45
Domestic hot water: COP, W/W 4.36–5.284.29–5.184.30–5.204.33–5.21
Cooling W23/18: capacity, kW 3.35–9.385.78–15.235.81–15.4510.48–22.60
Cooling W23/18: EER, W/W 2.82–3.312.75–3.192.78–3.212.82–3.31
Cooling W12/7: capacity, kW 2.64–6.884.55–11.204.67–11.808.25–19.00
Max. power input, kW 3.46.06.28.5
Max. operating current, A 15.527.310.414.3
Compressor / fan / pump Panasonic DC + EVI / DC / Grundfos DCPanasonic DC + EVI / DC / Grundfos DCPanasonic DC + EVI / DC / Grundfos DCPanasonic DC + EVI / DC / Grundfos DC
Max. water flow / head, m³/h / m 4 / 8.96 / 10.56 / 10.58 / 12.5
Max. water temperature, °C 75757575
Outdoor temperature range, °C −30…+50−30…+50−30…+50−30…+50
Refrigerant / charge, kg R290 / 0.8R290 / 1.3R290 / 1.3R290 / 2.0
Noise level (pressure at 1 m / power), dB(A) 45 / 5246 / 5346 / 5348 / 55
Water protection IPX4IPX4IPX4IPX4
Net / gross weight, kg 89 / 95126 / 145126 / 145178 / 205
Dimensions (L×W×H), mm 1185×435×8481255×435×13941255×435×13941255×435×1480

Specifications are based on manufacturer data under standard test conditions and are subject to change.